Emporia vue install. 1 second data is retained 3 hours, 1 minute data is retained 7 days, 1 hour data is retained. Emporia vue install

 
 1 second data is retained 3 hours, 1 minute data is retained 7 days, 1 hour data is retainedEmporia vue install  Ive got esphome to install through the terminal on my pc

Turn off. Edit configmcsMQTT. Articles to help understand how the Gen 2 works as well as troubleshooting. two vertically adjacent (stacked) 15A single. 2; 2; 2 months, 1 week ago. The Vue system is designed for field installation in a switch enclosure as per 312. A. The Vue Energy Monitor is connected directly to your electric meter and monitors its readings 24/7. That means the conduit must be pullable - you must put appropriate sweeps or "conduit bodies" (corners or Tees with access covers) where they'll be needed. . This means that our advanced users can choose to build up their own dashboards and use the pieces from the energy dashboard that they like. 0. Some installation notes: I used off-the-shelf mono audio extension cables for the far sensors. If you are using the [magico13/ha-emporia-vue] integration in Home Assistant, the data will already be appearing in the InfluxDb database. Here’s What You Get. Do You have Metal Bus Bar Mains in Your Panel? Our Flexible Current Sensor solution is now available on the EmporiaEnergy website . 25"x 2. Vue sensors provide 1-second data and are accurate from ±2%. About 12h of work for the 11 Vue 2s and all the CTs inside the panels. Share installation photos. 1. i have a bunch of android programs running inside of Bluestacks. 99, we have worked hard to make that platform available to all! PRODUCTS Vue Energy Monitor WIRELESS ENERGY MONITOR EV Charger EV Charger w/ Load MGMT EV Charger w/ ProControl V2X Bi-Directional Charger Smart Plugs PowerStation Battery BUS Bars and Combo boxes. Vue does not support IE8 and below, because it uses ECMAScript 5 features that are un-shimmable in IE8. Even with two Vues 2 at 32 channels, some balanced 240V loads (AC compressor and EV charger) need to be doubled with one clamp – which is perfectly fine and accurate. Standby generators, or Solar monitoring. Ensure. Can the Emporia Vue (gen 2) be installed in a standard UK setup, and does it work?0:00 Intro1:08 Setup at No. Anther home energy monitor: Sense – EnergyAlso, since it’s about 36″ high, the cables are a bit too short, they would need to be about 6″ longer. Installation is easy, with a simple plug-and-play process that takes just <30 minutes. Ensure. If anyone would like to buy and try , there is 10% off from official website : ten%offk. Bring this data into the Home Assistant Energy Portal and build beautiful graphs in Gra. @mattclar, are you sure you didn’t change the uart section of your yaml file? It should look like: # This uart connects to the MGM111 uart: id: emporia_uart rx_pin: GPIO21 tx_pin: GPIO22 baud_rate: 115200 There is a very small chance that emporia has a new version of the board and moved the serial port around, I’d confirm that you board. If Sense had a way to force-program over a short period of time I probably would have gone with Sense. + Show more. The Emporia Vue is installed in a separate weatherproof. This panel has a subpanel that leads to my large garage. Setup a Gen 2 for Sub-Metering. Tenants on a separate meter: Install a Gen 2 Vue in a panel where the tenant is responsible for all of the usage in that panel. Installed an Emporia Vue power monitoring device over the weekend. Level 2 charging is completed with a 240V circuit, similar to what you use to power an electric oven or dryer. That panels has 12 breakers. . Solar Monitoring. Emporia Vue: Gen 2 with 8 Sensors and Pair of Flexible Current Sensors Regular price $174 99 $174. ENERGY DATA: REQUIRES 2. In my install, I had two leads and used the included plug to cover the C port. Unofficial library for interacting with the Emporia Vue energy monitor. This is in the newest addition. This PDF guide will walk you through the steps of setting up the Gen 2 Emporia Vue and its sensors, clamps, and cables. xyz. py --chip esp32 erase_flash. The Emporia Vue smart home energy monitor is a cost-effective way to keep track of energy activity in your house. However it supports all ECMAScript 5 compliant browsers. Ensure. defaultfilters: - &throttle_avg # average all raw readings together over a 5 second span before publishing throttle_average: 5s - &throttle_time # only send the most recent measurement every 60 seconds throttle: 60s - &invert # invert and filter out any. Works with all electric cars. . Works with all electric cars. Once HA comes back up, navigate to one of your dashboards. Welcome back to KwhOnly-EV. EN. It monitors the main feed consumption and up to 8 (or 16 in the newer version) individual branch circuits, and feeds that data back to the Emporia API server. Page 17 Step 10: Complete setup with the app Go back to the Emporia Energy app on your phone or tablet. Released: Jul 14, 2023 Unofficial library for interacting with the Emporia Vue energy monitor. 4 GHz WIFI WITH AN INTERNET CONNECTION to monitor energy use with iPhone / Android app. 6" x 0. THE FIRST 200 PEOPLE TO PURCHASE AN ENERGY MONITOR GET A $30 BILL CREDIT FROM CFU! By purchasing this product from Emporia, you agree to allow Emporia to share your name and address with Cedar Falls Utilities so they can issue bill credit; if eligible. 00 Shop EV Chargers + Installation!The Emporia EV Charging Station is a Level 2 charger, the standard for home EV charging. Readme License. Then add one webpage card and paste the link from above. When you finish configuring the Utility Meter, 4 helpers will be created, 3 sensors (one for each peak) and 1 Select helper. It comes with a 24’ cable with an SAE. Usage: upgrade [options] [plugin-name] (experimental) upgrade vue cli service / plugins Options: -t, --to <version> Upgrade <plugin-name> to a version that is not latest -f, --from <version> Skip probing installed plugin, assuming it is upgraded from the designated version -r, --registry <url> Use specified. It can be upgraded to the solar variant anytime for 50 bucks. js による大規模アプリケーションを構築するときには、NPM を利用したインストールを推奨しています。. I have a net-metered solar array with battery backup (Darfon inverter and battery system), and a subpanel for loads to power by battery backup during grid. CT Sensors - Bi-directional current detection. Affordable Whole Home Power Monitoring with the Emporia Energy Vue 2 Review and how to use it locally with ESPHome and Home Assistant. If you do not see it in the list, ensure that you have installed the integration. Then you’ll connect the Vue to your nearby Wi-Fi network. The most important thing to remember is, TURN OFF THE MAIN BREAKER TO THE PANEL YOU ARE INSTALLING IT IN. Technical specifications for Emporia Gen 2 Vue, Emporia EV Charger, Emporia V2X Charger, Alpha-ESS Home Battery Systems, Emporia Current Sensors, Vue Utility Connect, and Emporia Smart Plugs. 5mm. The following command dumps the entire flash: $ esptool. Level 2 charges any EV up to 48 amps. Lower your electric bills! With the Emporia Vue Real Time 24/7 Electricity Monitor for the home. Based on your comment it seems you like the Emporia devices and would recommend that 16 channel energy monitor? Install PyEmVue from command line with “pip install pyemvue” in command/terminal window. Solar net metering is built right into the Emporia Vue. 02728. Obviously the Vue2 needs Wifi and internet *while on generator* and in most cases, after the fridge and sump pumps, that’ll be. or Buy on Amazon. CT Sensors - Bi-directional current detection. Multiply these fees times the number of units and costs can rise quickly. Do not install the Emporia Vue in environments with explosive gas or vapors; nor in damp or wet environments; nor in direct sunlight; nor where temperatures are consistently below -40° F (-40° C) or above 122° F (50° C). Yes - the Gen 2 is fairly flexible in this way. py --chip esp32 write_flash -z 0x1000 myvue. If you did the install while the solar was ‘on’ please perform a WiFi Reset/Solar Set up on the app. Next, connect the second breaker. Do not install the Emporia Vue in environments with explosive gas or vapors; nor in damp or wet environments; nor in direct sunlight; nor where temperatures are consistently below -40° F (-40° C) or above 122° F (50° C). or. Recently, I noticed it was offline, and it will not re-connect. Instead of trying to figure out what runs based on listening to the two mains only, Emporia provides you with up to sixteen extra sensors, you can add directly to the circuits of your electricity panel. If you believe any of the Emporia Vue components may have been damaged, do not attempt to use them. I recently installed a Gen2 with 16 sensor in a house panel with some Solar inputs, and I thought I would share my experience to add some details to the installation guide. Installed behind your home's main breaker box, the Vue works in any market. Once i got pyemvue to pull back my data, i setup the json file for vuegraf. A. 🛠️ Standard Tooling for Vue. Yes, you can use a breaker larger than 15A to power the Gen 2 Vue. Emporia’s system, however, costs much less than Sense’s: The Emporia Vue base unit is just $50, plus another $60 if you choose to add the eight circuit-specific sensors (you can buy the two. All you need to do is display the data like you want in Grafana. REAL-TIME ENERGY DATA: REQUIRES 2. See all 14 articles. Emporia Vue. 99. 8. In this video I show you how to setup and integrate the Emporia Vue Utility Connect with #HomeAssistant. Emporia has developed the next generation of the Vue Energy Monitor. We recommend using a licensed electrician. Vue sensors provide 1-second data and are accurate from ±2%. So I. Hope this helps! Emporia Installation Guides. or . This device is a smart energy monitor, which allows me to moni. Emporia Vue: Utility Connect for Select Markets Regular price $39 99 $39. $8499. 1. Learn how to install the Emporia Vue Gen 2 flexible current sensors with this detailed manual. (Update: this is now called “ View type ” in newer HA versions. If you believe any of the Emporia Vue components may have been damaged, do not attempt to use them. Setup and Installation. MIT license Activity. It comes with a 24’ cable. Then, plug the AC adapter into the. Brand: EMPORIA ENERGY. However, if you don’t have a solar installation at the moment, you can opt for the non-solar Sense monitor. It comes with a 24’ cable with an SAE J1772 connector so it works with all electric cars. Emporia Vue: The Cost-effective Electric Sub-meter for Rental Units. The Emporia – Vue is a whole house electricity usage monitor that lets you track eight individual circuits with each sensor module. The Emporia App also suggests valuable savings. ‍Learn More Only $399. Emporia Vue. 99 at Amazon. Emporia users have reported saving 15-20% on their power bills by monitoring their homes with this device. 5mm. Instructions are found here —> GitHub - jertel/vuegraf: Populate metrics from your Emporia Vue energy monitoring devices into an InfluxDB Notes: I did not use the container install… however, agree that’s preferred if you are comfortable with containers. Emporia Smart Plugs are now in the UK and EU. Emporia has promised updates to better handle multiple non-nested Vue2’s. Black harness wire and an extra wire with a. 0 for home energy monitoring of 120/240V loads. All the benefits of Sense, plus; Dedicated circuit monitoring, or. Page 1 Emporia Vue Utility Connect User Guide Installation Guide Device Release Notes. Committed to bringing the best value at the lowest price possible, the Vue provides everything you need to monitor your entire home's energy usage in real time, as well as 8 extra sensors to allow you to monitor individual circuits. Installation was not difficult, but it was slightly time consuming (took me around 2 hours). It was easy to install and configure and it integrated into HA without issue. Tap the settings menu (three lines just below the Emporia logo), tap Manage Devices, Select Your Device, tap the Reset WiFi/Solar Setup. Setup a Gen 2 for. This powerful automation can be used to run automations at specific intervals at specific times of day. 5mm Y adapter to get to 400A, but given that all 3 of the 3. Metrics are then natively exposed in Prometheus format from HomeAssistant, and the result is this glorious dashboard. - 0. kandi ratings - Low support, No Bugs, 26 Code smells, Permissive License, Build available. Emporia has developed the next generation of the Vue Energy Monitor. I decided to go with the Vue Utility Connect ($39) which communicates with supported electric meters over ZigBee. Unlike the Enphase CTs that just show you your total load, production, in/out from grid, the Vue 2 has. 5mm for the 200A sensors and 2. 1 second data is retained 3 hours, 1 minute data is retained 7 days, 1 hour data is retained. IoTaWatt vs Emporia Vue 2. This is an unauthorized and unoffical firmware for the Emporia View Utility Connect device that reports energy usage to Home Assistant and completely divorces the device from Emporia's servers. Top Features. The last step is to install Grafana, which we will use as a visualization tool. Make sure your phone is within 30 feet of the Vue. To elevate your energy monitoring to a grand finale, consider complementing your Vue with Emporia Smart Plugs, available separately. Go back to the Emporia Energy app on your phone or tablet. Just bought 5 Vue 2 units w/16 CTs each for a big install… but, haven’t used Vue before. Note: This project is not associated with or endorsed by Emporia Energy. Installation instructions are here: Setting up Emporia Vue 2 with ESPHome · GitHub. Ive double checked and my vue just inst coming online on my wifi. We recommend using a licensed electrician. keys as seen below or using a cron alike expression like * /5 * * * *. Schedule charging, track energy use, automate charge reduction for Peak Demand and Time-of-Use and Solar only Charging in the Emporia app. The Emporia setup process went without a hitch, and the app is well-designed. Snapshot of activity from each clamp-on sensor is captured every second. House or flat with electricity bills of > Rs 5000, Emporia Vue Gen2 can help identify exactly where and how your electricity is being used. 4. Do not attempt to open, disassemble, or repair any of the components of the Emporia Vue. Project description. I have a Hybrid Solar system with a Battery, and therefore I have a Sub panel with the house critical. The Gen 2 Vue is capable of net metering solar. Even without thinking about the savings, the ability to run monitors on 8 individual circuits, and work with some inexpensive smart monitoring plugs, made this Emporia the right one for me. So it should work for most electrical installations. Data is pulled from the Emporia API using the PyEmVue python module, also written by me. Emporia Emct-3p-exp-16, Top Best Home Automation Modules for UPB in 2023 (Reviews) FindThisBest, Home Power Monitoring with the Emporia VUE and Home Home 2023-11-25Easy Installation Guide for Emporia Vue Gen 2 Energy Monitor • Quick Emporia Vue Gen 2 Installation Guide • Discover the simple steps to install the Emporia. Vue. If you believe any of the Emporia Vue components may have been damaged, do not attempt to use them. BTW : HACS itself is a custom integration, how to install you find here : hacs. The Emporia Energy Vue is a terrific energy monitor device. js cung cấp một CLI giúp nhanh chóng khởi tạo nền tảng (scaffolding) cho các ứng dụng một trang. Share installation photos. I have an Emporia Vue gen 2 whole-home energy monitor, and it's great. Would probably be good to setup a reader account for grafana to the influxdbHome Assistant Integration for Emporia Vue Energy Monitor - GitHub - magico13/ha-emporia-vue: Home Assistant Integration for Emporia Vue Energy Monitor. What are the limits of the Emporia sensors? Our sensors have physical limitations. 3. The Emporia is a 48-amp unit, however, out of the box it comes with a NEMA 14-50 plug attached. You can see at the bottom that I had the time scale set to seconds. Semantic Versioning. 25" (82mm x 55mm x 55mm) Lower your electric bills! With the Emporia Vue Real Time 24/7 Electricity Monitor for the home. Go back to the Emporia Energy app on your phone or tablet. 99. EN. Does my Gen 2 need a multiplier on "mains" for a 240V system? CT Sensors - Proper alignment, placement. Do not install the Emporia Vue in environments with explosive gas or vapors; nor in damp or wet environments; nor in direct sunlight; nor where temperatures are consistently below -40° F (-40° C) or above 122° F (50° C). If you have a line-side tap, you need those CT’s on the upstream (utility) side of the taps. Start Your Journey in Three Easy Steps Step 1: Try Emporia's Software Download Emporia's home energy app on either the App Store or Google Play. the Vue and Expansion Module are unable to detect the amperage. The Emporia Gen 2 Vue monitors renewable energy net metering out of the box, giving you clear measurements of how much energy is being returned to the grid (and saving you money). If you can change out a circuit breaker, you can probably install this yourself. If you prefer a plain HTML setup without any build steps, you can use this JSFiddle as your starting point. If Sense had a way to force-program over a short period of time I probably would have gone with Sense. The Emporia Vue Smart Home Energy Monitor contains FCC ID: 2AS6P-EMCTV2 This device complies with. 1) Mains clamps: Arrow points from grid->panel. 25″ would probably be easier. The Gen 2 Vue from Emporia is a low-cost way to understand and manage your tenants energy use. Good value (IMO) for $165. Need Help. 3. Install a 15A or 20A dual breaker for the Emporia in the those lower left two free spots. Professional installation recommended. With the 50A sensors, you can also monitor your energy generation in real time and historically by the minute, hour, day, week, month, and year. . If you’re interested in solar, knowing your. I’m stuck with the firmware creation part in step 3. Installation of these sensors, however, remains a complex composition best entrusted to a licensed electrician or a qualified professional. Emporia Vue: Utility Connect for Select Markets. comon_time Trigger¶. If there were more of them I might try something more structured. Schedule charging, track energy use, automate charge reduction for Peak Demand and Time-of-Use and Solar only Charging in the Emporia app. Affiliate link: Get 5% off (plus I get 5%) by using this link: monitors are a great way to figure out what in your house is. Easy to export raw data to CSV files. 5mm coaxial WiFi connector 1m cable with 3. 022 = 0. Python Library for the Emporia Vue Energy Monitor Resources. I’m trying to decide between IoTaWatt and Emporia 2. 8(B) of the 2017 NEC regarding Power Monitoring Equipment. Any user can. I like to add each circuit to the consumption. All the benefits of Sense, plus; Dedicated circuit monitoring, or. 6. All My Favorite Tools - I wanted to crank up my ability to monitor the energy consumption in my home and deci. This is best done by a professional or competent home owner. The former costs more than the latter. The Emporia Vue app for whole-house electricity monitoring. CT Sensors - Monitoring Dual-Pole/Multi-Pole Circuits and using Multipliers. Professional installation recommended. The Vue is UL and CE Listed for your safety. I’ve seen @djwakelee mention using two 200A CTs in parallel through a 3. Vues emporiaEmporia monitor wifi vac Emporia 50a vue. Unofficial library for interacting with the Emporia Vue energy monitor. . Released: Jul 14, 2023 Hello, I have 2 x 200A panels, PNL. Select “ Panel (1 card) ” here). Disconnect the EN and IO0 cables from ground. Report bugs. Note: This project is not associated with or endorsed by Emporia Energy. There is another project to grab the data off Emporia into Home Assistant. 1 PNL. Let’s discuss using Vue Gen 2 with a backup generator. We recommend using a licensed electrician. The open H ome A utomation B us (openHAB, pronounced ˈəʊpənˈhæb) is an open source, technology agnostic home automation platform which runs as the center of your smart home! Some of openHAB's strengths are: Its ability to integrate a multitude of other devices and systems. Hardware and Installation (266, 794) Emporia App (172, 423). 1″ conduit is just big enough for the ell-shaped CT plugs to wiggle through even when you already have seven. If you believe any of the Emporia Vue components. Back in August I purchased a vue2, sniffed the data, took it apart, downloaded an updated. Another interesting option, although it won’t work for most people, is the Emporia “Vue Utility Connect wireless energy monitor. py version works. Click on Panel title. If there were more of them I might try something more structured. Details about the hardware setup of the Gen 2. 5 out of 5 stars 3,793 ratings. 5mm. I borrowed a few ideas from here after not liking my first installation. Easily install and get suggestions on how to save today!Emporia Vue2 at Amazon(sponsored): Lever Nuts: an Amazon Associate, I earn from qualifying purchasesHow. Emporia Vue Account - Username and password for the Emporia Vue system are required. 77 MB Table of Contents. I just put in the Emporia Vue 2 home energy monitoring system, actually to be able to monitor our new heat pump HVAC. I’m trying to install my new Emporia Gen 2 vue into a standard domestic consumer unit, yet when switching the breaker on, the RCD for the breakers trips. flyoffacliff. NETWAR wanted to kick things up a notch for 40. Emporia Flexible Current Sensor can be purchased as a kit to replace the 200A main sensors of your Gen 2 Vue or you can buy bundled with a Vue. Note possible variation between Windows and Linux described above to have success with the install. 6" (65mm x 44mm x 41mm) Window diameter: 1" (26mm) Cable length: 39" (1m) Connector plug: 3. I really like it, it's great to have power data. 08 kWh) and compared it with the Emporia measurement (3. Committed to bringing the best value at the lowest price possible, the Vue provides everything you need to monitor your entire home's energy usage in real time with 200A load sensors, as well as optional 50A sensors to allow you to monitor. Do not use the Emporia Vue in any manner other than specified in this installation guide. Relies on private commercial website which could be both harvesting data (seems it is per the privacy policy) and subject to future subscription cost…Sc00bs110 (Sc00bs110) July 19, 2021, 11:48am 21. (Use/Create Google account to log in) 3) Install “Emporia Energy” from Play Store. Emporia Vue 2 Installation. 99 Save $13 or . wire nut. Operates regardless of your utility. 39" (10mm) Cable length: 39" (1m) Connector plug: 2. Chỉ mất vài phút, bạn đã có thể bắt đầu xây dựng ứng dụng với các tính năng như hot-reload. It reports. I would wire the 4 power supply ac wires to a 120/240V plug outside the unit. For undocumented. It may be difficult to install the Vue Basic Unit, along with two sensors, a power adapter, and related wireless equipment, inside the box. Great for Energy savings, real time utility bills, solar installations and net metering. ( except for major holidays) Chat: Support Chat. We recommend using a licensed electrician. Download Emporia's app; Purchase and install the Emporia Vue; Follow Emporia's recommendations; Now let's learn about the Emporia app! The Graph Screen. 5mm. If you believe any of the Emporia Vue components may have been damaged, do not attempt to use them. . Step 3: Plug in the Vue Plug the USB dongle of the energy monitor into the USB port of the AC adapter. Feb 20, 2023. Jul 6, 2021. I decided to go with the Vue Utility Connect ($39) which communicates with supported electric meters over ZigBee. I’ve contacted Emporia and they suggested the I should connect the red and blue to the neutral bar that the black power wire is associated with and the white neutral wire should be in the. The "L" side should point towards appliance/consumption load and "K" represents power source. Enter your InfluxDB query in the Query editor. With Vue modified to use esphome you would have an equivalent starting point to IotaWatt — metrics on a local service. The Emporia EV Charger with Load Management consists of the award-winning Emporia Level 2 Smart Home EV Charger and an Emporia Vue Energy Monitor pre-enabled with Load Management capabilities. I’d start though with an Emporia Vue and get some hard data on power usage. Emporia Vue: Gen 2 Whole Home Energy Monitor. 5mm. Starting at less than $85! * Professional installation recommended. Maybe this will help someone else get it right the first time. Install Emporia Vue Energy Monitor for my home (How the Gen 2 Vue Energy Monitor Works). Page 17 Step 10: Complete setup with the app Go back to the Emporia Energy app on your phone or tablet. The Emporia Vue2’s main CT’s have to measure the net. 7" x 1. HAOS on Rasbperry Pi 4 - installed following standard instructions. Creates a sensor for each device channel showing average usage over each minute. wire nut. REAL-TIME ENERGY DATA: REQUIRES 2. Author. Does my Gen 2 need a multiplier on "mains" for a 240V system? CT Sensors - Proper alignment, placement. Comes with sixteen (16) 50A sensors to monitor individual circuits - Add up to eight more. The Vue monitors the total energy use and solar net metering of your home through a simple iOS or Android app. 65K subscribers Subscribe 10K views 1 year ago Emporia Vue:. Install the Bluestacks android emulator program on your PC. io. Granular 1-second data interval. The former costs more than the latter. bin. Click “Start” and then click “Open Web UI”. All (2581) Featured. txt from within each of the git folders to make sure i had all the requirements 7. 4 GHz WIFI WITH AN INTERNET CONNECTION to monitor energy use with iPhone / Android / Web app. 1 second data is retained 3 hours, 1 minute data is retained 7 days, 1 hour data is retained. Create a entity in Homeassistant ESPHome addon. CT Sensors - Bi-directional current detection. Just like our existing electric and natural gas meters, smart meters record your energy usage. Viewing 1 reply thread. Professional Installation: DIY compatible. consuming a lot of space inside the cracker box. 8(B) of the 2017 NEC regarding Power Monitoring Equipment. It's all thanks to the energy management and automation features we've baked into to our Smart Plugs, allowing you. 99 – $279. . Emporia, a Colorado-based smart home energy management technology company, in conjunction with the Consumer Product Safety Commission, has proactively recalled a batch of their award-winning smart plugs out of an abundance of caution. Emporia Vue. Emporia Smart Plug Review, Emporia Vue energy monitor review: Understand your home's energy consumption without breaking the bank TechHive, Emporia Vue Home Energy Monitor review Install a private detective for energy use The Gadgeteer. MSRP $9. The Emporia Vue Gen 2 also uses two sensors attached to your mains, but it comes with 16 additional sensors that you’ll attach to individual circuits inside your electrical panel. Would. Big thanks to @ Oceanwolf for originally mentioning the tool here. . Emporia Vue Energy Monitor Installation. I would guess So as long as the emporia cloud is up you can copy data to HA. pkg and it will install VUE.